Chapter 2
Selecting Output Interface
2.3.3 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If
no response within the specified period of time, the scanner will attempt to send the
same data three more times. If all the attempts fail without any notification, data loss
will occur.
1) Read the label above to specify the time interval for the scanner to send data and
wait for a response from the host.
2) Read the “
Decimal Value” label on page 192. For example, read “1” and “0” for the
scanner to automatically shut down after being idle for 1 second.
3) Read the “Validate” label on the same page to complete this setting.
ACK/NAK Error Beep
Note: We suggest enabling the error beep so that you will be notified of such data loss
and have the scanner re-read data.
2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE
After the scanner has established a connection as a SPP slave device, you may have it
read the “Activate BT SPP, Master Mode” setup label to switch to SPP Master Mode. This
will result in easy and reliable re-connection, just like connecting with the cradle.
ACK/NAK Time
-
O
ut after …
(
*0 ~ 99)
Enable Error Beep
*
Disable Error Beep