2 Enter Setup Metapace S-2 Hardware Manual GETTING FAMILIARIZED WITH METAPACE S-2 AND THE CRADLE INSTALLING THE BATTERY When you first receive the pa
92 Enter Setup Metapace S-2 Hardware Manual 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection
93 Update Chapter 3 Setting up a WPAN Connection 4. Turn on the scanner with correct WPAN settings, such as select BT SPP or BT HID, broadcast
94 Enter Setup Metapace S-2 Hardware Manual 6. Wait for a few seconds for the Wizard to search available devices nearby. The scanner will appear wi
95 Update Chapter 3 Setting up a WPAN Connection 8. Enter the passkey for authentication, which must be exactly the same as configured for the
96 Enter Setup Metapace S-2 Hardware Manual 10. Click [Finish]. Bluetooth SPP Only
97 Update Chapter 3 Setting up a WPAN Connection 11. Now the target scanner will be listed as shown below. You can have up to seven scanners c
98 Enter Setup Metapace S-2 Hardware Manual 12. Run the desired application on your computer, such as HyperTerminal.exe if using BT SPP or Notepad.ex
99 Update In this chapter, a brief on the symbology settings is provided for your reference. IN THIS CHAPTER 4.1 Codabar ...
100 Enter Setup Metapace S-2 Hardware Manual 4.1 CODABAR 4.1.1 START/STOP CHARACTERS SELECTION Select one of the four different start/stop characte
101 Update Chapter 4 Changing Symbology Settings 4.1.2 START/STOP TRANSMISSION Decide whether to include the start/stop characters in the data
3 Update Introduction SETTING UP THE CRADLE Capable of charging the Metapace S-2 scanner, the cradle is specifically designed for the scanner t
102 Enter Setup Metapace S-2 Hardware Manual 4.2 CODE 25 – INDUSTRIAL 25 4.2.1 START/STOP PATTERN SELECTION This decides the readability of all 2 o
103 Update Chapter 4 Changing Symbology Settings 4.2.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode
104 Enter Setup Metapace S-2 Hardware Manual 4.2.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible
105 Update Chapter 4 Changing Symbology Settings 4.3 CODE 25 – INTERLEAVED 25 4.3.1 START/STOP PATTERN SELECTION This decides the readabilit
106 Enter Setup Metapace S-2 Hardware Manual 4.3.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be
107 Update Chapter 4 Changing Symbology Settings 4.3.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it i
108 Enter Setup Metapace S-2 Hardware Manual 4.4 CODE 25 – MATRIX 25 4.4.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5
109 Update Chapter 4 Changing Symbology Settings 4.4.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode
110 Enter Setup Metapace S-2 Hardware Manual 4.4.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible
111 Update Chapter 4 Changing Symbology Settings 4.5 CODE 39 4.5.1 START/STOP TRANSMISSION Decide whether to include the start/stop characte
4 Enter Setup Metapace S-2 Hardware Manual --- Blue, solid Connected with the scanner Red, solid Blue, flashing Failed to send data to host via USB
112 Enter Setup Metapace S-2 Hardware Manual 4.5.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
113 Update Chapter 4 Changing Symbology Settings 4.6 CODE 93 You can only configure the scanner to read this symbology or not. 4.7 CODE 128
114 Enter Setup Metapace S-2 Hardware Manual 4.8 EAN-8 *Enable EAN-8 (No Addon) Disable EAN-8 (No Addon) *Disable EAN-8 Addon 2 *Disabl
115 Update Chapter 4 Changing Symbology Settings 4.8.1 CONVERT TO EAN-13 Decide whether to expand the read EAN-8 barcode, as well as its addon
116 Enter Setup Metapace S-2 Hardware Manual 4.9 EAN-13 Disable EAN-13 (No Addon) *Disable EAN-13 Addon 2 *Disable EAN-13 Addon 5 Enable
117 Update Chapter 4 Changing Symbology Settings 4.9.1 ISBN CONVERSION Decide whether to convert the EAN-13 barcode, starting with 978 and 979
118 Enter Setup Metapace S-2 Hardware Manual 4.9.4 SECURITY LEVEL Select the security level for reading EAN-13 barcodes.
119 Update Chapter 4 Changing Symbology Settings 4.10 GS1-128 (EAN-128) 4.10.1 CODE ID TRANSMISSION Decide whether to include the Code ID (&
120 Enter Setup Metapace S-2 Hardware Manual Note: GS1-128 barcodes start with the FNC1 control character to distinguish themselves from other uses
121 Update Chapter 4 Changing Symbology Settings 4.12 MSI 4.12.1 VERIFY CHECK DIGIT Select one of the three calculations to verify check dig
5 Update Introduction CHARGING BATTERY VIA THE CRADLE The battery may not be charged to full for shipment. When you first receive the package,
122 Enter Setup Metapace S-2 Hardware Manual 4.12.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
123 Update Chapter 4 Changing Symbology Settings 4.12.3 CODE LENGTH QUALIFICATION Because of the weak structure of the symbology, it is possib
124 Enter Setup Metapace S-2 Hardware Manual 4.13 FRENCH PHARMACODE 4.13.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the da
125 Update Chapter 4 Changing Symbology Settings 4.14 ITALIAN PHARMACODE 4.14.1 TRANSMIT CHECK DIGIT Decide whether to include the check di
126 Enter Setup Metapace S-2 Hardware Manual 4.15 PLESSEY 4.15.1 CONVERT TO UK PLESSEY Decide whether to change each occurrence of the character &a
127 Update Chapter 4 Changing Symbology Settings 4.16 GS1 DATABAR (RSS FAMILY) 4.16.1 CODE ID SELECTION Select a desired Code ID to use – GS1
128 Enter Setup Metapace S-2 Hardware Manual Application ID Transmission Decide whether to include the Application ID ("01") in the data be
129 Update Chapter 4 Changing Symbology Settings Code ID Transmission Decide whether to include the Code ID in the data being transmitted.
130 Enter Setup Metapace S-2 Hardware Manual Application ID Transmission Decide whether to include the Application ID ("01") in the data be
131 Update Chapter 4 Changing Symbology Settings 4.17 TELEPEN 4.17.1 TELEPEN OUTPUT – FULL ASCII/NUMERIC Decide whether to support Telepen i
6 Enter Setup Metapace S-2 Hardware Manual INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the b
132 Enter Setup Metapace S-2 Hardware Manual 4.18 UPC-A Disable UPC-A (No Addon) *Disable UPC-A Addon 2 *Disable UPC-A Addon 5 Enable UP
133 Update Chapter 4 Changing Symbology Settings 4.18.1 CONVERT TO EAN-13 Decide whether to expand the read UPC-A barcode, as well as its addo
134 Enter Setup Metapace S-2 Hardware Manual 4.19 UPC-E Disable UPC-E (No Addon) *Disable UPC-E Addon 2 *Disable UPC-E Addon 5 Enable U
135 Update Chapter 4 Changing Symbology Settings 4.19.1 SYSTEM NUMBER SELECTION Decide whether to decode the ordinary UPC-E barcodes only or b
136 Enter Setup Metapace S-2 Hardware Manual 4.19.3 SYSTEM NUMBER TRANSMISSION Decide whether to include the system number in the data being transmit
137 Update You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processe
138 Enter Setup Metapace S-2 Hardware Manual 5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first characte
139 Update Chapter 5 Defining Output Format 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUTION 1) Read the label above to enable character subs
140 Enter Setup Metapace S-2 Hardware Manual 5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be perf
141 Update Chapter 5 Defining Output Format Character Substitution for ISBT 128 Character Substitution
7 Update Introduction SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually en
142 Enter Setup Metapace S-2 Hardware Manual Character Substitution for EAN-13 Addon 5 Character Substitution
143 Update Chapter 5 Defining Output Format Character Substitution for MSI Character Substitution for P
144 Enter Setup Metapace S-2 Hardware Manual Character Substitution for UPC-A Addon 5 Character Substitution f
145 Update Chapter 5 Defining Output Format 5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return)
146 Enter Setup Metapace S-2 Hardware Manual 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID c
147 Update Chapter 5 Defining Output Format UPC-A J A A A E MSI V V D P M Plessey W W E Q P Telepen Z --- --- --- --- 5.4.2 CHANG
148 Enter Setup Metapace S-2 Hardware Manual Configure Code ID for CodabarConfigure Code ID for Code 39Configure Code ID for Code 93Confi
149 Update Chapter 5 Defining Output Format 5.4.3 CLEAR CODE ID SETTINGS Clear All Code ID SettingsConfigure Code ID for Inte
150 Enter Setup Metapace S-2 Hardware Manual 5.5 LENGTH CODE A two-digit code representing the length of barcode data (character count) can be insert
151 Update Chapter 5 Defining Output Format Length Code for EAN-8 Length Code for EAN-13
8 Enter Setup The configuration of the scanner can be done by reading the setup labels contained in this manual or via the software Metapace S-2.exe.
152 Enter Setup Metapace S-2 Hardware Manual Length Code for MSI Length Code for Plessey
153 Update Chapter 5 Defining Output Format 5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows you to decide the output sequence of a co
154 Enter Setup Metapace S-2 Hardware Manual 5.6.1 EDIT A CONCATENATION OF BARCODES 1) Read the label above to start editing a concatenation of ba
155 Update Chapter 5 Defining Output Format 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concat
156 Enter Setup Metapace S-2 Hardware Manual 5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching cha
157 Update The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fie
158 End Programming Format Metapace S-2 Hardware Manual 6.1 ACTIVATING EDITING FORMATS 6.1.1 ACTIVATE EDITING FORMATS If you have already configured
159 Update Chapter 6 Applying Formats for Data Editing Editing Format 4 Editing Format 5 6.1.2 EXCLUSIVE DATA EDI
160 End Programming Format Metapace S-2 Hardware Manual 6.2 HOW TO CONFIGURE EDITING FORMATS
161 Update Chapter 6 Applying Formats for Data Editing 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Fo
9 Update Quick Start Working Mode Upon powering up, the scanner will try to establish a connection with the cradle or a computer with Bluetooth
162 End Programming Format Metapace S-2 Hardware Manual 6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults
163 Update Chapter 6 Applying Formats for Data Editing 6.3 CONFIGURING FORMAT — DEFINE DATA CRITERIA Three applicable conditions can be config
164 End Programming Format Metapace S-2 Hardware Manual Editing Format for GS1-128 & GS1 DataBar Editing Format fo
165 Update Chapter 6 Applying Formats for Data Editing Editing Format for EAN-13 Addon 5 Editing Format for Fren
166 End Programming Format Metapace S-2 Hardware Manual Editing Format for Plessey Editing Format for Telepen
167 Update Chapter 6 Applying Formats for Data Editing Editing Format for UPC-E Addon 5 6.3.2 DATA LENGTH The le
168 End Programming Format Metapace S-2 Hardware Manual 6.3.3 MATCHING STRING & LOCATION By default, no matching string is specified, and theref
169 Update Chapter 6 Applying Formats for Data Editing 6.4 CONFIGURING FORMAT — DEFINE DATA FIELD 6.4.1 START POSITION Data can be divided int
170 End Programming Format Metapace S-2 Hardware Manual 6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numb
171 Update Chapter 6 Applying Formats for Data Editing 6.4.4 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-s
10 Enter Setup Metapace S-2 Hardware Manual ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the "
172 End Programming Format Metapace S-2 Hardware Manual Field 2 Setting 1. Read the above label to divide field by a specified terminating string
173 Update Chapter 6 Applying Formats for Data Editing Field 3 Setting 1. Read the above label to divide field by a specified terminating s
174 End Programming Format Metapace S-2 Hardware Manual Field 4 Setting 1. Read the above label to divide field by a specified terminating string
175 Update Chapter 6 Applying Formats for Data Editing Field 5 Setting 1. Read the above label to divide field by a specified terminating s
176 End Programming Format Metapace S-2 Hardware Manual Additional Fields Up to five additional fields can be created for each editing format; each
177 Update Chapter 6 Applying Formats for Data Editing 6.5 CONFIGURING FORMAT — DEFINE TRANSMISSION SEQUENCE After configuring the data fields
178 End Programming Format Metapace S-2 Hardware Manual 3) Read the “End” label to complete this setting. End
179 Update Chapter 6 Applying Formats for Data Editing 6.6 PROGRAMMING EXAMPLES 6.6.1 EXAMPLE I Extract data from the 10th character to the 19
180 End Programming Format Metapace S-2 Hardware Manual 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes.
181 Update Optical Characteristics Metapace S-2 Scan Engine Non-contact type Optical Sensor CCD, 2500 pixels Light Source Visible red LED RF
11 Update Quick Start DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you mus
182 Enter Setup Metapace S-2 Hardware Manual Electrical Characteristics Battery Rechargeable Li-ion battery – 3.7 V, 800 mAh Power Adapter Input AC
183 Update SCANNER SERIAL COMMANDS D Purpose To disable the scanner. Remarks “D” E Purpose To enable the scanner. Remarks “E” #@ nnnnnn <CR&
184 Enter Setup Metapace S-2 Hardware Manual #@TRIGOFF<CR> Purpose To disable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” +
185 Update Appendix I Host Serial Commands CRADLE SERIAL COMMANDS Normally, you can configure the cradle by having a connected scanner read crad
186 Enter Setup Metapace S-2 Hardware Manual DefaultSetting<CR> Purpose To restore the default settings. Remarks SingleConnection<CR> P
187 Update Appendix I Host Serial Commands Version<CR> Purpose To get the firmware versions (CPU+USB Bridge). Remarks GetID<CR> Pu
188 Enter Setup Metapace S-2 Hardware Manual EXAMPLE Without using the scanner to read the above setup labels for configuring the cradle, you may run
189 Update 0 1 2 3 4 5 6 7 8 0 F2 SP 0 @ P ` p 1 INS F3 ! 1 A Q a q 2 DLT F4 " 2 B R b r 3 Home F5 # 3
190 Enter Setup Metapace S-2 Hardware Manual KEY TYPE & STATUS KEY TYPE If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, K
191 Update Appendix II Keyboard Wedge Table EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character “!” as the prefix code
Copyright © 2010 EQUATOR LIMITED All rights reserved. All intellectual property rights are the property of their owners. EQUATOR LIMITED is authori
12 Enter Setup Metapace S-2 Hardware Manual READ A SETUP LABEL CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to
192 Enter Setup DECIMAL SYSTEM Decimal Validate the Values Appendix III NUMERAL SYSTEMS 0 1
193 Appendix III Numeral Systems Update AbortHEXADECIMAL SYSTEM Hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D
194 Enter Setup Metapace S-2 Hardware Manual Validate the Values ASCII TABLE 0 1 2 3 4 5 6 7 0 DLE SP 0 @ P ` p 1 SOH DC1 ! 1 A Q
195 Appendix III Numeral Systems Update AbortENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode,
196 Enter Setup Metapace S-2 Hardware Manual DISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the label below to disable auth
197 Appendix III Numeral Systems Update AbortReject Random PIN Request When the random PIN is displayed on the target device whi
13 Update Quick Start The example below shows how to save your settings as “User Default” so that you may restore user defaults at a later time
14 Enter Setup Metapace S-2 Hardware Manual The example below shows how to set numeric parameters: Steps Action User Feedback if Successful 1 Power
15 Update Quick Start The example below shows how to set string parameters: Steps Action User Feedback if Successful 1 Power on the scanner..
16 Enter Setup Metapace S-2 Hardware Manual LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer
17 Update Quick Start List settings regarding Editing Format 1 List settings regarding Editing Format 2 List settings regarding Editing F
18 Enter Setup This chapter explains the features and usage of the barcode scanner. IN THIS CHAPTER 1.1 Battery...
19 Update Chapter 1 Understanding the Barcode Scanner 1.1.2 AUTO POWER OFF & POWER-SAVING The scanner will stay active at power-on, which
20 Enter Setup Metapace S-2 Hardware Manual 1) Read the label above to specify the time interval before the scanner automatically turns off. 2) R
21 Update Chapter 1 Understanding the Barcode Scanner 1.2 MEMORY The collected data can be sent back to a host computer one by one via the WPA
SAFETY PRECAUTIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. The use
22 Enter Setup Metapace S-2 Hardware Manual 1.2.2 MEMORY MODE The scanner keeps 512 KB flash memory for memory mode operation. When the scanner is in
23 Update Chapter 1 Understanding the Barcode Scanner Send Data The 512 KB flash memory on the scanner can store up to 32,768 scans based
24 Enter Setup Metapace S-2 Hardware Manual 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For exampl
25 Update Chapter 1 Understanding the Barcode Scanner 1.3.1 GOOD READ LED 1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays
26 Enter Setup Metapace S-2 Hardware Manual 1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating conditions. Beeping Mea
27 Update Chapter 1 Understanding the Barcode Scanner 1.4.1 BEEPER VOLUME Mute Medium Volume*Maximum VolumeMinimum Volume
28 Enter Setup Metapace S-2 Hardware Manual 1.4.2 GOOD READ BEEP Frequency Duration 8 kHz * 4 kHz 2 kHz 1 kHz *Shortest Longer Longest Sh
29 Update Chapter 1 Understanding the Barcode Scanner 1.4.3 LOW BATTERY ALARM By default, it will activate the beeper to give a warning when t
30 Enter Setup Metapace S-2 Hardware Manual 1.5 SEND “NR” TO HOST The scanner can send the “NR” string to the host to notify the No Read event.
31 Update Chapter 1 Understanding the Barcode Scanner 1.6 SCAN MODES Different scan modes are supported – select the scan mode that best suits
CONTENTS IMPORTANT NOTICES ... -
32 Enter Setup Metapace S-2 Hardware Manual 1.6.1 CONTINUOUS MODE The scanner is always scanning. After a successful decoding, the removal of barc
33 Update Chapter 1 Understanding the Barcode Scanner 1.6.2 TEST MODE The scanner is always scanning. Capable of decoding the same barcode
34 Enter Setup Metapace S-2 Hardware Manual 1.6.5 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed. The scanning wo
35 Update Chapter 1 Understanding the Barcode Scanner 1.6.7 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held dow
36 Enter Setup Metapace S-2 Hardware Manual 1.7 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is se
37 Update Chapter 1 Understanding the Barcode Scanner 1.8 DELAY BETWEEN RE-READ This is also referred to as the “Blocking Time”, which is used
38 Enter Setup Metapace S-2 Hardware Manual 1.9 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example, If "No
39 Update Chapter 1 Understanding the Barcode Scanner 1.10 ADDON SECURITY FOR UPC/EAN BARCODES You may like to enforce read redundancy (0~30 t
40 Enter Setup Metapace S-2 Hardware Manual 1.11 AUTO-SENSE MODE When the scanner is seated in the cradle, press the trigger so that it will automati
41 Update Chapter 1 Understanding the Barcode Scanner 1.12 CCD SENSOR ALWAYS ACTIVE This feature is used to keep the CCD sensor always active
Metapace S-2 Hardware Manual 1.6.5 Auto Power Off Mode ...
42 Enter Setup Metapace S-2 Hardware Manual 1.14 EFFECTIVE DECODING AREA By default, the effective decoding area is 100% covered by the scanned area.
43 Update Chapter 1 Understanding the Barcode Scanner Percentage for Right Half Right 10% Right 20% *Right 50% Right 40% Right 30% Le
44 Enter Setup In order to establish a proper connection between your computer and the scanner, we suggest that you follow these instructions – 1)
45 Update Chapter 2 Selecting Output Interface 2.1 BT HID For BT HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection
46 Enter Setup Metapace S-2 Hardware Manual BT HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —
47 Update Chapter 2 Selecting Output Interface 2.1.3 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lo
48 Enter Setup Metapace S-2 Hardware Manual French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row”
49 Update Chapter 2 Selecting Output Interface Note: This setting is to be used with the Character Substitution setting when support to ce
50 Enter Setup Metapace S-2 Hardware Manual Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard i
51 Update Chapter 2 Selecting Output Interface Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Selec
Metapace S-2 Hardware Manual 2.6.3 Inter-Function Delay...
52 Enter Setup Metapace S-2 Hardware Manual Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON&
53 Update Chapter 2 Selecting Output Interface 2.1.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value
54 Enter Setup Metapace S-2 Hardware Manual 2.2 BT SPP SLAVE For BT SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection for related connecti
55 Update Chapter 2 Selecting Output Interface 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK
56 Enter Setup Metapace S-2 Hardware Manual 2.3 BT SPP MASTER As a SPP master device, the scanner will be able to resume connection with the host upo
57 Update Chapter 2 Selecting Output Interface Note: Read the “Set Connection” label first, and then the “MAC ID” label within 10 seconds. In
58 Enter Setup Metapace S-2 Hardware Manual 2.3.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging
59 Update Chapter 2 Selecting Output Interface 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK
60 Enter Setup Metapace S-2 Hardware Manual 2.4 KEYBOARD WEDGE VIA THE CRADLE The Y cable allows you to connect the scanner via the cradle to the key
61 Update Chapter 2 Selecting Output Interface Keyboard Wedge via the Cradle By default, the keyboard type is set to PCAT (US). The following
Metapace S-2 Hardware Manual 4.9.3 Transmit Check Digit...
62 Enter Setup Metapace S-2 Hardware Manual US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower
63 Update Chapter 2 Selecting Output Interface Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US
64 Enter Setup Metapace S-2 Hardware Manual Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboa
65 Update Chapter 2 Selecting Output Interface Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that t
66 Enter Setup Metapace S-2 Hardware Manual Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric
67 Update Chapter 2 Selecting Output Interface 2.4.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a v
68 Enter Setup Metapace S-2 Hardware Manual 2.5 RS-232 VIA THE CRADLE Use the RS-232 cable to connect the scanner via the cradle to the serial port o
69 Update Chapter 2 Selecting Output Interface 2.5.3 DATA BITS 2.5.4 PARITY * 8 bits 7 bits *No Parity 2400 bps 9600 bps 4800 bps 1200
70 Enter Setup Metapace S-2 Hardware Manual 2.5.5 STOP BIT 2.5.6 FLOW CONTROL By default, there is no flow control in use. Select the flow contro
71 Update Chapter 2 Selecting Output Interface 2.5.7 INTER-CHARACTER DELAY By default, the inter-character delay is zero. Specify a value,
Metapace S-2 Hardware Manual 5.7 Removal of Special Character ...
72 Enter Setup Metapace S-2 Hardware Manual 1) Read this label above to specify the inter-function delay. 2) Read the “Decimal Value” label o
73 Update Chapter 2 Selecting Output Interface 2.6 USB HID VIA THE CRADLE For USB HID, use the USB cable to connect the scanner via the cradle
74 Enter Setup Metapace S-2 Hardware Manual USB HID via the Cradle By default, the keyboard type is set to PCAT (US). The following keyboard types ar
75 Update Chapter 2 Selecting Output Interface 2.6.2 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lo
76 Enter Setup Metapace S-2 Hardware Manual French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row”
77 Update Chapter 2 Selecting Output Interface Note: This setting is to be used with the Character Substitution setting when support to c
78 Enter Setup Metapace S-2 Hardware Manual Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard i
79 Update Chapter 2 Selecting Output Interface Ignore Case*Case-sensitive Refer to 5.1 Letter Case.
80 Enter Setup Metapace S-2 Hardware Manual Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric
81 Update Chapter 2 Selecting Output Interface 2.6.3 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value
1 Update The Metapace S-2 scanner is specifically designed to answer your mobile demands. The versatile scanners are designed to help accelerate
82 Enter Setup Metapace S-2 Hardware Manual 2.7 USB VIRTUAL COM VIA THE CRADLE Use the USB cable to connect the scanner via the cradle to the USB por
83 Update Chapter 2 Selecting Output Interface 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK
84 Enter Setup The Metapace S-2 scanner can be configured to send data to a host computer wirelessly via the cradle, or to a notebook computer or PDA
85 Update Chapter 3 Setting up a WPAN Connection IN THIS CHAPTER 3.1 Connecting via the Cradle ... 85
86 Enter Setup Metapace S-2 Hardware Manual 3.1.2 CHANGE INTERFACE If you want to change the interface cable of the cradle, use one of the scanners t
87 Update Chapter 3 Setting up a WPAN Connection 3.1.3 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enable
88 Enter Setup Metapace S-2 Hardware Manual 3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to configure the scann
89 Update Chapter 3 Setting up a WPAN Connection Device Name Broadcasting The scanner can be configured to hide itself from other devices equi
90 Enter Setup Metapace S-2 Hardware Manual Authentication When any changes are made to authentication and PIN code on the scanner side, you will hav
91 Update Chapter 3 Setting up a WPAN Connection Entering preset PIN code… 1. Read the “Use preset PIN” label to enable authentication with a
Comentários a estes Manuais